- Products
- Markets
- Services & Tools
- Newsroom
- CSR
- Blog
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
Nexans H07Z1-U Cca / H07Z1-R Cca type 2 450/750V
Nexans H07Z1-U Cca / H07Z1-R Cca type 2 450/750V
Nexans H07Z1-U Cca Type 2 and Nexans H07Z1-R Cca Type 2 are halogen-free and fire-retardant installation wire for 450 / 750V AC or 1kV DC. H07Z1-U has a solid class 1 core, H07Z1-R has a stranded class 2 core. Nexans H07Z1-U/R Cca Type 2 is intended for protected fixed domestic and industrial installations. Installation may be in a tube or in closed gutters embedded in the wall, in the floor or surface mounted.
Nexans H07Z1-U/R Cca Type 2 has fire reaction class Cca-s1,d2,a1 according to EN 50575 and may be installed in bundle or side by side and in areas with increased fire risk according to AREI/RGIE. The wire is also suited for areas where AREI/RGIE imposes s1 a1.
ALSECURE® H07Z1-U Cca 1x4 GREY TYPE 2
Nexans ref. 10559560
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Grey
- Conductor cross-section: 4 mm²
- Permissible current rating in open air: 32 A
- Voltage drop, single phase: 9.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x4 BLUE TYPE 2 NEW
Nexans ref. 10559561
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Blue
- Conductor cross-section: 4 mm²
- Permissible current rating in open air: 32 A
- Voltage drop, single phase: 9.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x4 BLACK TYPE 2 NEW
Nexans ref. 10559563
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Black
- Conductor cross-section: 4 mm²
- Permissible current rating in open air: 32 A
- Voltage drop, single phase: 9.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x4 GN/YE TYPE 2 NEW
Nexans ref. 10559570
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Green / yellow
- Conductor cross-section: 4 mm²
- Permissible current rating in open air: 32 A
- Voltage drop, single phase: 9.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x4 BROWN TYPE 2 NEW
Nexans ref. 10559571
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Brown
- Conductor cross-section: 4 mm²
- Permissible current rating in open air: 32 A
- Voltage drop, single phase: 9.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 BLACK TYPE 2
Nexans ref. 10540474
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Black
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 BLUE TYPE 2
Nexans ref. 10540477
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Blue
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 BROWN TYPE 2
Nexans ref. 10540479
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Brown
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 GREY TYPE 2
Nexans ref. 10540490
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Grey
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 GN/YE TYPE 2
Nexans ref. 10540491
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Green / yellow
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 1 m
ALSECURE® H07Z1-U Cca 1x6 GN/YE TYPE 2 R100
Nexans ref. 10540492
- Packaging: Ring (100m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Green / yellow
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 100 m
ALSECURE® H07Z1-U Cca 1x6 BLACK TYPE 2 B10km
Nexans ref. 10543954
- Packaging: Drum (10000m)
- Conductor flexibility: Solid class 1
- Conductor shape: Round, massive
- Wire colour: Black
- Conductor cross-section: 6 mm²
- Permissible current rating in open air: 41 A
- Voltage drop, single phase: 6.2 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor
- U.V resistance: No
- Length: 10000 m
ALSECURE® H07Z1-R Cca 1x16 GN/YE TYPE 2
Nexans ref. 10538834
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 16 mm²
- Permissible current rating in open air: 76 A
- Voltage drop, single phase: 2.3 V/A.km
- Bending factor when laying: 4 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x25 GN/YE TYPE 2
Nexans ref. 10538835
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 25 mm²
- Permissible current rating in open air: 101 A
- Voltage drop, single phase: 1.5 V/A.km
- Bending factor when laying: 5 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x35 GN/YE TYPE 2
Nexans ref. 10538852
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 35 mm²
- Permissible current rating in open air: 125 A
- Voltage drop, single phase: 1.2 V/A.km
- Bending factor when laying: 5 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x50 GN/YE TYPE 2
Nexans ref. 10538838
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 50 mm²
- Permissible current rating in open air: 151 A
- Voltage drop, single phase: 0.84 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x70 GN/YE TYPE 2
Nexans ref. 10538839
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 70 mm²
- Permissible current rating in open air: 192 A
- Voltage drop, single phase: 0.6 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x95 GN/YE TYPE 2
Nexans ref. 10538837
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 95 mm²
- Permissible current rating in open air: 232 A
- Voltage drop, single phase: 0.46 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x120 GN/YE TYPE 2
Nexans ref. 10538853
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 120 mm²
- Permissible current rating in open air: 269 A
- Voltage drop, single phase: 0.38 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x150 GN/YE TYPE 2
Nexans ref. 10538850
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 150 mm²
- Permissible current rating in open air: 309 A
- Voltage drop, single phase: 0.33 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x185 GN/YE TYPE 2
Nexans ref. 10538851
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 185 mm²
- Permissible current rating in open air: 353 A
- Voltage drop, single phase: 0.28 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
ALSECURE® H07Z1-R Cca 1x240 GN/YE TYPE 2
Nexans ref. 10538836
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor shape: Round, stranded
- Wire colour: Green / yellow
- Conductor cross-section: 240 mm²
- Permissible current rating in open air: 415 A
- Voltage drop, single phase: 0.24 V/A.km
- Bending factor when laying: 6 (xD)
- Field of application: Indoor, Outdoor
- U.V resistance: EN 50289-4-17 method A, for 720h
- Length: 1 m
Description
Description
Standards
-
ProductEN 50525-3-31
Application
- Halogenfree insulated conductors for fixed installations
- For domestic and industrial applications as well as for panel wiring
Design
- Copper core, solid (U) or stranded (R)
- Halogen free and fire retardant insulating sheath
Installation
- In industries
- In houses
- Open-air laying : with protection
- Ground laying : with protection
Note only for Nexans H07Z1-R Cca Type 2
UV resistance according to EN 50289-4-17 Method A (test duration 720h) establishes Nexans H07Z1-R Cca Type 2 is particularly fitted for our Belgian climate. Nexans H07Z1-R Cca Type 2 can thus be exposed to direct sunlight. This UV resistance is valid for the Nexans H07Z1-R Cca Type 2 accompanied by the Declaration of Performance (DoP) n°1000277-BEDO.
More on UV resistance
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics