- Products
- Markets
- Services & Tools
- Newsroom
- CSR
- Blog
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
YMvK Dca-s2 ULTRAFLEX 0.6/1 kV 5G16 mm2
YMvK Dca-s2 ULTRAFLEX 0.6/1 kV 5G16 mm2
YMvK ss Dca ULTRAFLEX® is a power cable according to fire classification Dca-s2,d2,a3, for usage in low voltage installations up to 0.6/1 kV in housing, residential and similar installations with a medium fire hazard level
Read more- Nexans ref. : 10559997
- EAN : 5413404322787
Description
Description
Standards
-
ProductHD 604.4D; IEC 60228; IEC 60502
-
TestKEMA 42 C-1-4-D
Applications
YMvK ss Dca ULTRAFLEX® is a power cable according to fire classification Dca-s2,d2,a3, for usage in low voltage installations up to 0.6/1 kV in housing, residential and similar installations with a medium fire hazard level. YMvK ss Dca ULTRAFLEX® is suitable for fixed installation in sight, with clamps or saddles. Use of this cable in special trays and ducts is allowed. This cable has a reduced propagation of fire in cable bunches..
Declaration of Performance
Reaction to fire: Dca-s2,d2,a3
Design
- Conductor
Bare copper
Highly flexible, class 2 (Conductor construction according to IEC 60228 class 5, conductor resistance according to class 2) - Insulation: XLPE
- Inner covering filling compound or filler compound
- Outer sheath: PVC
Colour: grey
UV resistance: Yes
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current capacity table PR three phase multicore NL
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
16.0 | 68.0 | 80.0 | 96.0 | 75.0 | 84.0 | 100.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
D1 Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR single phase multicore
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
16.0 | 76.0 | 91.0 | 107.0 | 91.0 | 100.0 | 115.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
D1 Multi-core cable in ducts in the ground |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR single phase single core
Conductor cross-section | ||||
---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu |
16.0 | 81.0 | 100.0 | 107.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
F Single-core flat cables, touching in free air |
Current capacity table PR three phase single core
Conductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
16.0 | 73.0 | 88.0 | 96.0 | 75.0 | 84.0 | 0.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
D1 Single or Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Single or Multi-core cables designed to be buried directly in the ground |
F Single-core trefoil cables, touching in free air |
F Single-core flat cables, touching in free air |
Selling & delivery Information
Marking
YMvK ss Dca-s2,d2,a3
n (x or G) s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking
n = no. of conductors
s = cross section in mm²
x = without green/yellow
G = with green/yellow
Declaration of Performance
- Declaration of Performance n� : 1000904-BEDO
- Certification Date : 12/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : NB 2659
- Declared performance : Dca-s2,d2,a3
Dealer locator
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania