YMvK Dca-s2 ULTRAFLEX 0.6/1 kV 1x185 mm2

Description

Description

Standards

  • Product
    HD 604.4D; IEC 60228; IEC 60502
  • Test
    KEMA 42 C-1-4-D

Applications

YMvK ss Dca ULTRAFLEX® is a power cable according to fire classification Dca-s2,d2,a3, for usage in low voltage installations up to 0.6/1 kV in housing, residential and similar installations with a medium fire hazard level.  YMvK ss Dca ULTRAFLEX®  is suitable for fixed installation in sight, with clamps or saddles. Use of this cable in special trays and ducts is allowed. This cable has a reduced propagation of fire in cable bunches..

Design

  1. Conductor
    Bare copper
    Highly flexible, class 2 (Conductor construction according to IEC 60228 class 5, conductor resistance according to class 2)
  2. Insulation: XLPE 
  3. Inner covering filling compound or filler compound 
  4. Outer sheath: PVC
    Colour: grey
    UV resistance: Yes

Performance class

Declaration of Performance

Reaction to fire: Dca-s2,d2,a3

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Highly flexible, class 2
Conductor shape
Round, multi stranded
Insulation
XLPE (chemical)
Protection
Filler
Outer sheath
PVC
Sheath colour
Grey
Lead free
Yes
Core identification
Natural
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Conductor cross-section
185 mm²
Outer Diameter
23.6 mm
Approximate weight
1940 kg/km
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
0.099 Ohm/km
Permissible current rating in open air
510 A
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Minimum installation temperature
0 °C
Operating temperature, range
-20 ... 80 °C
Max. conductor temperature in service
90 °C
Bending factor when laying
8 (xD)
Field of application
Fixed installations
U.V resistance
EN 50289-4-17 method A, for 720h

Resources

Resources

Current capacity table PR three phase multicore NL

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu
185.0 295.0 340.0 424.0 281.0 324.0 456.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
D1 Multi-core cable in ducts in the ground
C Single-core or multi-core cable on a wooden wall
D2 Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Current capacity table PR single phase multicore

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu
185.0 329.0 384.0 506.0 343.0 387.0 542.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
D1 Multi-core cable in ducts in the ground
D2 Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Current capacity table PR single phase single core

Conductor cross-section
mm² Cu Cu Cu Cu
185.0 362.0 449.0 506.0 575.0
A1 Insulated conductors in conduit in a thermally insulated wall
B1 Insulated conductors in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
F Single-core flat cables, touching in free air

Current capacity table PR three phase single core

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu
185.0 324.0 384.0 424.0 281.0 324.0 510.0 533.0
A1 Insulated conductors in conduit in a thermally insulated wall
B1 Insulated conductors in conduit on a wooden wall
D1 Single or Multi-core cable in ducts in the ground
C Single-core or multi-core cable on a wooden wall
D2 Single or Multi-core cables designed to be buried directly in the ground
F Single-core trefoil cables, touching in free air
F Single-core flat cables, touching in free air

Selling & delivery Information

Marking

YMvK ss Dca-s2,d2,a3
n (x or G) s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking

n = no. of conductors

s = cross section in mm²

x = without green/yellow

G = with green/yellow

 

 

Declaration of Performance

  • Declaration of Performance n� : 1000904-BEDO
  • Certification Date : 12/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB 2659
  • Declared performance : Dca-s2,d2,a3

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close