YMvK Dca-s2 0.6/1 kV 4G16 mm2

Description

Description

Standards

  • Product
    HD 604.4D; IEC 60228
  • Test
    KEMA 42 C-1-4-D

Applications

YMvK Dca 0.6/1 kV is a power cable for general use in construction works subject to performance requirements on reaction to fire. YMvK Dca 0.6/1 kV is suitable for application in low voltage installations up to 0.6/1 kV, according to NEN 1010. It meets the requirements according to fire classification Dca-s2,d2,a3 for usage in buildings and civil engineering works with a medium fire hazard level (NEN 8012).
Thanks to its improved flexibility YMvK Dca-s2 FLEX 0.6/1 kV is easier to install then the non-flexible version. YMvK Dca FLEX 0.6.1 kV is available from 35 mm2.

YMvK Dca-s2 0.6/1 kV Easy Strippable has an improved design with an easier to strip cable sheaths. With Easy Strippable you can remove the sheath in a single smooth motion over a length of up to 100 cm. 

Design

  1. Conductor:
    Conductors untill 10 mm2: Bare copper, solid, class 1
    Conductors from 10 mm2: Bare copper, stranded, class 2 
  2. Insulation: XLPE
  3. Inner covering: filling compound 
  4. Outer sheath: PVC
    Colour: Grey
    UV resistance: Yes

Characteristics

Characteristics

Construction characteristics

Construction characteristics

With Green/Yellow core
Yes
Core identification
Brown, black, grey, green / yellow
Sheath colour
Grey
Conductor shape
Round, multi stranded
Conductor material
Bare copper
Insulation
XLPE (chemical)
Protection
Filler
Outer sheath
PVC
Conductor flexibility
Stranded class 2
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
4
Conductor cross-section
16 mm²
Approximate weight
930 kg/km
Nominal outer diameter
21.1 mm
Average insulation thickness
0.7 mm
Nominal outer sheath thickness
1.8 mm

Electrical characteristics

Electrical characteristics

Loop resistance, max. at 20°C
1.15 Ohm/km
Permissible current rating in open air
100 A
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Field of application
Standard
Bending factor when laying
10 (xD)
One single bending at each end minimum
8 (xD)
Minimum installation temperature
0 °C
Operating temperature, range
-20 ... 80 °C
Max. conductor temperature in service
90 °C
Packaging
Cut to length
U.V resistance
EN 50289-4-17 method A, for 720h

Resources

Resources

Current capacity table PR single phase single core

Conductor cross-section
mm² Cu Cu Cu Cu
16.0 81.0 100.0 107.0 0.0
A1 Insulated conductors in conduit in a thermally insulated wall
B1 Insulated conductors in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
F Single-core flat cables, touching in free air

Current capacity table PR single phase multicore

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu
16.0 76.0 91.0 107.0 91.0 100.0 115.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
D1 Multi-core cable in ducts in the ground
D2 Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Current capacity table PR three phase single core

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu
16.0 73.0 88.0 96.0 75.0 84.0 0.0 0.0
A1 Insulated conductors in conduit in a thermally insulated wall
B1 Insulated conductors in conduit on a wooden wall
D1 Single or Multi-core cable in ducts in the ground
C Single-core or multi-core cable on a wooden wall
D2 Single or Multi-core cables designed to be buried directly in the ground
F Single-core trefoil cables, touching in free air
F Single-core flat cables, touching in free air

Current capacity table PR three phase multicore NL

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu
16.0 68.0 80.0 96.0 75.0 84.0 100.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
D1 Multi-core cable in ducts in the ground
C Single-core or multi-core cable on a wooden wall
D2 Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Selling & delivery Information

Marking

YMvK Dca (FLEX) n (x or G) s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking

 

 

 

Declaration of Performance

  • Declaration of Performance n� : 1000903-BEDO
  • Certification Date : 12/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB 2659
  • Declared performance : Dca-s2,d2,a3

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close