- Products
- Markets
- Services & Tools
- Newsroom
- CSR
- Blog
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
YMvK Dca-s2 0.6/1 kV 8G2.5 MM2
YMvK Dca-s2 0.6/1 kV 8G2.5 MM2
Power cable according to Dutch standard with fire classification Dca-s2,d2,a3 for usage in low voltage installations up to 0.6/1 kV in housing, residential and simular installation with a medium fire hazard level
Read more- Nexans ref. : 10559867
- EAN : 5413404321490
Description
Description
Standards
-
ProductHD 604.4D; IEC 60228
-
TestKEMA 42 C-1-4-D
Applications
YMvK Dca 0.6/1 kV is a power cable for general use in construction works subject to performance requirements on reaction to fire. YMvK Dca 0.6/1 kV is suitable for application in low voltage installations up to 0.6/1 kV, according to NEN 1010. It meets the requirements according to fire classification Dca-s2,d2,a3 for usage in buildings and civil engineering works with a medium fire hazard level (NEN 8012).
Thanks to its improved flexibility YMvK Dca-s2 FLEX 0.6/1 kV is easier to install then the non-flexible version. YMvK Dca FLEX 0.6.1 kV is available from 35 mm2.
YMvK Dca-s2 0.6/1 kV Easy Strippable has an improved design with an easier to strip cable sheaths. With Easy Strippable you can remove the sheath in a single smooth motion over a length of up to 100 cm.
Design
- Conductor:
Conductors untill 10 mm2: Bare copper, solid, class 1
Conductors from 10 mm2: Bare copper, stranded, class 2 - Insulation: XLPE
- Inner covering: filling compound
- Outer sheath: PVC
Colour: Grey
UV resistance: Yes
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current capacity table PR single phase single core
Conductor cross-section | ||||
---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu |
2.5 | 26.0 | 31.0 | 33.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
F Single-core flat cables, touching in free air |
Current capacity table PR single phase multicore
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 25.0 | 30.0 | 33.0 | 33.0 | 35.0 | 36.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
D1 Multi-core cable in ducts in the ground |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR three phase single core
Conductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 23.0 | 28.0 | 28.0 | 30.0 | 30.0 | 0.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
D1 Single or Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Single or Multi-core cables designed to be buried directly in the ground |
F Single-core trefoil cables, touching in free air |
F Single-core flat cables, touching in free air |
Current capacity table PR three phase multicore NL
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 22.0 | 26.0 | 28.0 | 30.0 | 30.0 | 32.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
D1 Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Selling & delivery Information
Marking
YMvK Dca (FLEX) n (x or G) s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking
Declaration of Performance
- Declaration of Performance n� : 1000903-BEBU
- Certification Date : 12/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : NB 2659
- Declared performance : Dca-s2,d2,a3
Dealer locator
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania