ALSECURE® YMz1K B2ca / ALSECURE® YMz1K B2ca FLEX
ALSECURE® YMz1K B2ca / ALSECURE® YMz1K B2ca FLEX
YMz1K B2ca is a halogen free low smoke power cable according to fire classification B2ca-s1,d1,a1 for connection in low voltage installation up to 0.6/1 kV in construction works with a very high fire hazard level. YMz1K B2ca FLEX provided with conductors with increased bendability (FLEX)
Read moreNexans YMz1K B2ca 0.6/1 kV 3G1.5 mm2 Easy Strippable
Nexans ref. 10532898
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 10.6 mm
- Approximate weight: 207 kg/km
- Permissible current rating in open air: 23 A
- Loop resistance, max. at 20°C: 12.1 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G1.5 mm2 Easy Strippable
Nexans ref. 10532904
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 11.4 mm
- Approximate weight: 242 kg/km
- Permissible current rating in open air: 23 A
- Loop resistance, max. at 20°C: 12.1 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G1.5 mm2 Easy Strippable
Nexans ref. 10532909
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 12.1 mm
- Approximate weight: 280 kg/km
- Permissible current rating in open air: 23 A
- Loop resistance, max. at 20°C: 12.1 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 3G2.5 mm2 Easy Strippable (B500)
Nexans ref. 10532901
- Packaging: Drum (500m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 11.6 mm
- Approximate weight: 250 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 3G2.5 mm2 Easy Strippable
Nexans ref. 10532899
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 11.6 mm
- Approximate weight: 250 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G2.5 mm2 Easy Strippable
Nexans ref. 10532905
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 12.5 mm
- Approximate weight: 300 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G2.5 mm2 Easy Strippable (B500)
Nexans ref. 10532906
- Packaging: Drum (500m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 12.5 mm
- Approximate weight: 300 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G2.5 mm2 Easy Strippable
Nexans ref. 10532910
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 13.5 mm
- Approximate weight: 340 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G2.5 mm2 Easy Strippable (B500)
Nexans ref. 10532911
- Packaging: Drum (500m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 13.5 mm
- Approximate weight: 340 kg/km
- Permissible current rating in open air: 32 A
- Loop resistance, max. at 20°C: 7.41 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 3G4 mm2 Easy Strippable
Nexans ref. 10532902
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Nominal outer diameter: 12.6 mm
- Approximate weight: 315 kg/km
- Permissible current rating in open air: 42 A
- Loop resistance, max. at 20°C: 4.61 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G4 mm2 Easy Strippable
Nexans ref. 10532907
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Nominal outer diameter: 13.0 mm
- Approximate weight: 375 kg/km
- Permissible current rating in open air: 42 A
- Loop resistance, max. at 20°C: 4.61 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G4 mm2 Easy Strippable
Nexans ref. 10532912
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Nominal outer diameter: 14.0 mm
- Approximate weight: 440 kg/km
- Permissible current rating in open air: 42 A
- Loop resistance, max. at 20°C: 4.61 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 3G6 mm2 Easy Strippable
Nexans ref. 10532903
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Nominal outer diameter: 13.6 mm
- Approximate weight: 390 kg/km
- Permissible current rating in open air: 54 A
- Loop resistance, max. at 20°C: 3.08 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G6 mm2 Easy Strippable
Nexans ref. 10532908
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Nominal outer diameter: 14.7 mm
- Approximate weight: 475 kg/km
- Permissible current rating in open air: 54 A
- Loop resistance, max. at 20°C: 3.08 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G6 mm2 Easy Strippable
Nexans ref. 10532913
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor material: Bare copper
- Conductor shape: Round solid
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Nominal outer diameter: 16.2 mm
- Approximate weight: 555 kg/km
- Permissible current rating in open air: 54 A
- Loop resistance, max. at 20°C: 3.08 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G10 mm2
Nexans ref. 10532924
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Nominal outer diameter: 18.5 mm
- Approximate weight: 595 kg/km
- Permissible current rating in open air: 75 A
- Loop resistance, max. at 20°C: 1.83 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G10 mm2
Nexans ref. 10532928
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Nominal outer diameter: 20.3 mm
- Approximate weight: 780 kg/km
- Permissible current rating in open air: 75 A
- Loop resistance, max. at 20°C: 1.83 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G16 mm2
Nexans ref. 10532925
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Nominal outer diameter: 21.2 mm
- Approximate weight: 925 kg/km
- Permissible current rating in open air: 100 A
- Loop resistance, max. at 20°C: 1.15 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G16 mm2
Nexans ref. 10532929
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 5
- Conductor cross-section: 16 mm²
- Nominal outer diameter: 23.1 mm
- Approximate weight: 1125 kg/km
- Permissible current rating in open air: 100 A
- Loop resistance, max. at 20°C: 1.15 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 4G25 mm2
Nexans ref. 10532926
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 25.0 mm
- Approximate weight: 1345 kg/km
- Permissible current rating in open air: 127 A
- Loop resistance, max. at 20°C: 0.73 Ohm/km
Nexans YMz1K B2ca 0.6/1 kV 5G25 mm2
Nexans ref. 10532950
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, stranded
- Number of cores: 5
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 26.6 mm
- Approximate weight: 1595 kg/km
- Permissible current rating in open air: 127 A
- Loop resistance, max. at 20°C: 0.73 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x 35 mm2
Nexans ref. 10532951
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 12.5 mm
- Approximate weight: 405 kg/km
- Permissible current rating in open air: 201 A
- Loop resistance, max. at 20°C: 0.52 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x35 mm2
Nexans ref. 10532959
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 25.6 mm
- Approximate weight: 1490 kg/km
- Permissible current rating in open air: 158 A
- Loop resistance, max. at 20°C: 0.52 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G35 mm2
Nexans ref. 10532965
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1921 kg/km
- Permissible current rating in open air: 158 A
- Loop resistance, max. at 20°C: 0.52 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 5G35 mm2
Nexans ref. 10532973
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 5
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 30.6 mm
- Approximate weight: 2335 kg/km
- Permissible current rating in open air: 158 A
- Loop resistance, max. at 20°C: 0.52 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x50 mm2
Nexans ref. 10532952
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 13.6 mm
- Approximate weight: 530 kg/km
- Permissible current rating in open air: 246 A
- Loop resistance, max. at 20°C: 0.39 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x50 mm2
Nexans ref. 10532960
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 28.5 mm
- Approximate weight: 1950 kg/km
- Permissible current rating in open air: 192 A
- Loop resistance, max. at 20°C: 0.39 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G50 mm2
Nexans ref. 10532966
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 31.6 mm
- Approximate weight: 2475 kg/km
- Permissible current rating in open air: 192 A
- Loop resistance, max. at 20°C: 0.39 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 5G50 mm2
Nexans ref. 10532974
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 5
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3044 kg/km
- Permissible current rating in open air: 192 A
- Loop resistance, max. at 20°C: 0.39 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x70 mm2
Nexans ref. 10532953
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 15.8 mm
- Approximate weight: 715 kg/km
- Permissible current rating in open air: 318 A
- Loop resistance, max. at 20°C: 0.27 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x70 mm2
Nexans ref. 10532961
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 33.6 mm
- Approximate weight: 2723 kg/km
- Permissible current rating in open air: 246 A
- Loop resistance, max. at 20°C: 0.27 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G 70 mm2
Nexans ref. 10532967
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 37.3 mm
- Approximate weight: 3453 kg/km
- Permissible current rating in open air: 246 A
- Loop resistance, max. at 20°C: 0.27 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 5G70 mm2
Nexans ref. 10532975
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 5
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 41.3 mm
- Approximate weight: 4290 kg/km
- Permissible current rating in open air: 246 A
- Loop resistance, max. at 20°C: 0.27 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x95 mm2
Nexans ref. 10532954
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 1010 kg/km
- Permissible current rating in open air: 389 A
- Loop resistance, max. at 20°C: 0.19 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x95 mm2
Nexans ref. 10532962
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 37.3 mm
- Approximate weight: 3730 kg/km
- Permissible current rating in open air: 298 A
- Loop resistance, max. at 20°C: 0.19 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G95 mm2
Nexans ref. 10532968
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 41.5 mm
- Approximate weight: 4763 kg/km
- Permissible current rating in open air: 298 A
- Loop resistance, max. at 20°C: 0.19 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 5G95 mm2
Nexans ref. 10532976
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 5
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 5985 kg/km
- Permissible current rating in open air: 298 A
- Loop resistance, max. at 20°C: 0.19 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x120 mm2
Nexans ref. 10532955
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 19.5 mm
- Approximate weight: 1255 kg/km
- Permissible current rating in open air: 454 A
- Loop resistance, max. at 20°C: 0.15 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x120 mm2
Nexans ref. 10532963
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 40.8 mm
- Approximate weight: 4635 kg/km
- Permissible current rating in open air: 346 A
- Loop resistance, max. at 20°C: 0.15 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G120 mm2
Nexans ref. 10532969
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 45.6 mm
- Approximate weight: 5930 kg/km
- Permissible current rating in open air: 346 A
- Loop resistance, max. at 20°C: 0.15 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 5G120 mm2
Nexans ref. 10532977
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 5
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 51.2 mm
- Approximate weight: 7295 kg/km
- Permissible current rating in open air: 346 A
- Loop resistance, max. at 20°C: 0.15 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x150 mm2
Nexans ref. 10532956
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 21.9 mm
- Approximate weight: 1532 kg/km
- Permissible current rating in open air: 527 A
- Loop resistance, max. at 20°C: 0.12 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x150 mm2
Nexans ref. 10533080
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 45.9 mm
- Approximate weight: 5695 kg/km
- Permissible current rating in open air: 399 A
- Loop resistance, max. at 20°C: 0.12 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G150 mm2
Nexans ref. 10532970
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 7280 kg/km
- Permissible current rating in open air: 399 A
- Loop resistance, max. at 20°C: 0.12 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x185 mm2
Nexans ref. 10532957
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 24.2 mm
- Approximate weight: 1915 kg/km
- Permissible current rating in open air: 605 A
- Loop resistance, max. at 20°C: 0.1 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 3x185 mm2
Nexans ref. 10532964
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 51.2 mm
- Approximate weight: 7150 kg/km
- Permissible current rating in open air: 456 A
- Loop resistance, max. at 20°C: 0.1 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G185 mm2
Nexans ref. 10532971
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 57.1 mm
- Approximate weight: 9160 kg/km
- Permissible current rating in open air: 456 A
- Loop resistance, max. at 20°C: 0.1 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 1x240 mm2
Nexans ref. 10532958
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 25.8 mm
- Approximate weight: 2385 kg/km
- Permissible current rating in open air: 719 A
- Loop resistance, max. at 20°C: 0.08 Ohm/km
Nexans YMz1K B2ca FLEX 0.6/1 kV 4G240 mm2
Nexans ref. 10532972
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor material: Copper class 2
- Conductor shape: Round, multi stranded
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 63.7 mm
- Approximate weight: 11885 kg/km
- Permissible current rating in open air: 538 A
- Loop resistance, max. at 20°C: 0.08 Ohm/km
Description
Description
Standards
-
ProductHD 604 S1 part 5/sect. C; IEC 60228
Applications
Nexans YMz1K B2ca is a halogen free low smoke power cable for general use in construction works subject to performance requirements on reaction to fire. YMz1K B2ca is suitable for application in low voltage installations up to 0.6/1 kV, according to NEN 1010. It meets the requirements according to fire classification B2ca-s1,d1,a1 for buildings and civil engineering works with a very high fire hazard level (NEN 8012).
Available from 35 mm2: YMz1K B2ca FLEX, provided with conductors with increased bendability.
Main benefits
- Easy Strippable - Cables (1.5 - 6 mm2) are easy to strip
- PEP EcoPassport - EPD environmental passport available
- UV Resistant - Our cables passed the 720 hour test according to the test standard EN 50289-4-17 Method A
Design
- Conductor
Sections till 10 mm2: Bare copper, solid, class 1
Sections from 10 mm2: Bare copper, stranded, class 2 - Insulation: XLPE
Inner covering: Halogen free compound - Outer sheath: Halogen free compound
Colour: grey
UV resistance: Yes
Core identification
- 1 core: neutral
- 2 cores: brown-light blue
- 3G cores: green/yellow-brown-light blue
- 3x cores: black-grey-brown
- 4 cores: green/yellow - brown-black-grey
- 5 cores: green/yellow - light blue - brown - black - grey
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking
ALSECURE YMz1K B2ca n (x or G) s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking
Core identification
- 1 core: neutral
- 2 cores: brown-light blue
- 3G cores: green/yellow-brown-light blue
- 3x cores: black-grey-brown
- 4 cores: green/yellow - brown-black-grey
- 5 cores: green/yellow - light blue - brown - black - grey
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania