VO-YMvKas Dca-s2 0.6/1 kV 3X2.5 MM2
VO-YMvKas Dca-s2 0.6/1 kV 3X2.5 MM2
VO-YMvKas Dca-s2 is a braided power cable according to fire classification Dca-s2,d2,a3 for connection in low voltage installation up to 0.6/1 kV.
Read more- Nexans ref. : 10559891
- EAN : 5413404321735
Description
Description
Standards
-
ProductHD 604.4D; IEC 60228
-
TestKEMA 42 C-1-4-D
Applications
VO-YMvKas Dca-s2 0.6/1 kV is a braided power cable according to fire classification Dca-s2,d2,a3 for usage in low voltage installations up to 0.6/1 kV in housing, residential and similar installations with a medium fire hazard level. VO-YMvKas Dca-s2 is suitable for direct burial and is advised if protection against mechanical damage and EMI is demanded. This cable has a reduced propagation of fire in cable bundles.
Design
- Conductor: Bare copper, solid, class1
- Insulation: XLPE
- Inner covering: PVC
- Armour: Galvanized steel wire braiding with an underlaying drainwire of tinned copper
- Outer sheath: PVC
Colour: grey
UV resistance: Yes
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current capacity table PR single phase multicore
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 25.0 | 30.0 | 33.0 | 33.0 | 35.0 | 36.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
D1 Multi-core cable in ducts in the ground |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR single phase single core
Conductor cross-section | ||||
---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu |
2.5 | 26.0 | 31.0 | 33.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
F Single-core flat cables, touching in free air |
Current capacity table PR three phase multicore NL
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 22.0 | 26.0 | 30.0 | 28.0 | 30.0 | 32.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
D1 Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR three phase single core
Conductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 23.0 | 28.0 | 30.0 | 28.0 | 30.0 | 0.0 | 0.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
D1 Single or Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Single or Multi-core cables designed to be buried directly in the ground |
F Single-core trefoil cables, touching in free air |
F Single-core flat cables, touching in free air |
Selling & delivery Information
Marking
VO-YMvKas Dca n x s mm²
NEXANS BENELUX
KEMA KEUR
Meter Marking
Declaration of Performance
- Declaration of Performance n� : 1000907-BEBU
- Certification Date : 12/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : NB 2659
- Declared performance : Dca-s2,d2,a3