Nexans Z1O-YMz1Kas Cca 0.6/1 kV

Products

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 2x1.5/1.5 mm2 MTR

Nexans ref. 10572019

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 13.5 mm
  • DC permissible current rating: 26 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 3x1.5/1.5 mm2 MTR

Nexans ref. 10572023

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 14.0 mm
  • DC permissible current rating: 22 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 4x1.5/1.5 mm2 MTR

Nexans ref. 10572027

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 14.7 mm
  • DC permissible current rating: 22 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 5x1.5/1.5 mm2 MTR

Nexans ref. 10572031

  • Packaging: Cut to length (m)
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 14.7 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 6x1.5/1.5 mm2 MTR

Nexans ref. 10572035

  • Packaging: Cut to length (m)
  • Number of cores: 6
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 16.3 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 7x1.5/1.5 mm2 MTR

Nexans ref. 10572037

  • Packaging: Cut to length (m)
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 16.3 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 2x2.5/2.5 mm2 MTR

Nexans ref. 10572020

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 14.2 mm
  • DC permissible current rating: 34 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 3x2.5/2.5 mm2 MTR

Nexans ref. 10572024

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 14.7 mm
  • DC permissible current rating: 29 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 4x2.5/2.5 mm2 MTR

Nexans ref. 10572028

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 15.5 mm
  • DC permissible current rating: 29 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 5x2.5/2.5 mm2 MTR

Nexans ref. 10572032

  • Packaging: Cut to length (m)
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 15.7 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 6x2.5/2.5 mm2 MTR

Nexans ref. 10572036

  • Packaging: Cut to length (m)
  • Number of cores: 6
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 17.5 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 7x2.5/2.5 mm2 MTR

Nexans ref. 10572038

  • Packaging: Cut to length (m)
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 17.1 mm
  • DC permissible current rating: 21 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 2x4/4 mm2 MTR

Nexans ref. 10572021

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 15.2 mm
  • DC permissible current rating: 45 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 3x4/4 mm2 MTR

Nexans ref. 10572025

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 15.8 mm
  • DC permissible current rating: 37 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 4x4/4 mm2 MTR

Nexans ref. 10572029

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 16.7 mm
  • DC permissible current rating: 37 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 5x4/4 mm2 MTR

Nexans ref. 10572033

  • Packaging: Cut to length (m)
  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 17.1 mm
  • DC permissible current rating: - A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 2x6/6 mm2 MTR

Nexans ref. 10572022

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 16.2 mm
  • DC permissible current rating: 58 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 3x6/6 mm2 MTR

Nexans ref. 10572026

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 16.8 mm
  • DC permissible current rating: 46 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 4x6/6 mm2 MTR

Nexans ref. 10572030

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 17.9 mm
  • DC permissible current rating: 46 A

 

Nexans Z1O-YMz1Kas Cca 0.6/1 kV 5x6/6 mm2 MTR

Nexans ref. 10572034

  • Packaging: Cut to length (m)
  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 18.4 mm
  • DC permissible current rating: - A

 

Description

Description

Standards

  • Product
    HD 604 S1 part 5/sect. C; IEC 60228

Applications

Nexans Z1O-YMz1Kas Cca 0.6/1 kV is a braided power cable according to fire classification Cca-s1,d1,a1 for usage in low voltage installations up to 0.6/1 kV in buildings and civil engineering works with a high fire hazard level (NEN 8012).  ALSECURE Z1O-YMz1Kas Cca 0.6/1 kV is suitable for direct burial and is advised if protection against mechanical damage and EMI is demanded.

 

Main benefits

PEP EcoPassport - EPD environmental passport available
UV Resistant - Our cables passed the 720 hour test according to the test standard EN 50289-4-17 Method A

Design

  1. Conductor: Bare copper, solid, class 1
  2. Insulation: XLPE
  3. Inner covering: Halogen free compound
  4. Armour: Galvanized steel wire braiding with an underlaying drainwire of tinned copper
  5. Outer sheath: Halogen free compound with reduced fire propagation
    Colour: grey
    UV resistance: Yes

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Conductor flexibility
Solid class 1
Armour type
Galvanized steel wire braiding
Sheath colour
Grey
Halogen free
Yes

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Excellent

Usage characteristics

Usage characteristics

Bending factor when laying
10 (xD)
Fire retardant
IEC 60332-3
Minimum installation temperature
0 °C
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 80 °C
U.V resistance
EN 50289-4-17 method A, for 720h

Resources

Resources

Selling & delivery Information

Marking

Nexans Z1O-YMz1Kas Cca-s1,d1,a1 n x s
NEXANS BENELUX
KEMA KEUR +
Meter Marking

 

 

 

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close