- Products
- Markets
- Services & Tools
- Newsroom
- CSR
- Blog
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
VG-YMvKas Dca-s2 Flex 0.6/1kV 3x185 mm2
VG-YMvKas Dca-s2 Flex 0.6/1kV 3x185 mm2
VG-YMvKas Dca is an armoured power cable according to fire classification Dca-s2,d2,a3 for connection in low voltage installation up to 0.6/1 kV. VG-YMvKas Dca Flex is provided with conductors having increased bendability (FLEX)
Read more- Nexans ref. : 10559934
- EAN : 5413404322152
Description
Description
Standards
-
ProductHD 604.4D; IEC 60228
-
TestKEMA 42 C-1-4-D
Applications
VG-YMvKas Dca is an armoured power cable according to fire classification Dca-s2,d2,a3 for usage in low voltage installations up to 0.6/1 kV in housing, residential and simular installations with a medium fire hazard level. VG-YMvKas Dca is suitable for direct burial and is advised if protection against mechanical damage and EMI is demanded. This cable has a reduced propagation of fire in cable bunches.
Available from 35 mm2: VG-YMvKas Dca Flex, provided with conductors having increased bendability.
Design
- Conductor
Bare copper, stranded, class 2
Insulation: XLPE - Inner covering
PVC with filler extruded or PET foil for more 5 cond and sector shaped types - Armour
Galvanized steel wires and bare copper wire or Flat steel wires and flat bare copper wires covered with an open counter spiral of galvanized steel tape - Outer sheath
PVC
Colour: grey
UV resistance: Yes
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current capacity table PR single phase multicore
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
185.0 | 329.0 | 384.0 | 506.0 | 343.0 | 387.0 | 542.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
D1 Multi-core cable in ducts in the ground |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR single phase single core
Conductor cross-section | ||||
---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu |
185.0 | 362.0 | 449.0 | 506.0 | 575.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
C Single-core or multi-core cable on a wooden wall |
F Single-core flat cables, touching in free air |
Current capacity table PR three phase multicore NL
Conductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
185.0 | 295.0 | 340.0 | 424.0 | 281.0 | 324.0 | 456.0 |
A2 Multi-core cable in conduit in a thermally insulated wall |
B2 Multi-core cable in conduit on a wooden wall |
D1 Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Multi-core cables designed to be buried directly in the ground |
E Multi-core cable in free air |
Current capacity table PR three phase single core
Conductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
185.0 | 324.0 | 384.0 | 424.0 | 281.0 | 324.0 | 510.0 | 533.0 |
A1 Insulated conductors in conduit in a thermally insulated wall |
B1 Insulated conductors in conduit on a wooden wall |
D1 Single or Multi-core cable in ducts in the ground |
C Single-core or multi-core cable on a wooden wall |
D2 Single or Multi-core cables designed to be buried directly in the ground |
F Single-core trefoil cables, touching in free air |
F Single-core flat cables, touching in free air |
Selling & delivery Information
Marking
VG-YMvKas Dca
n x s
NEXANS BENELUX
KEMA KEUR
Meter Marking
Declaration of Performance
- Declaration of Performance n� : 1000905-BEDO
- Certification Date : 12/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : NB 2659
- Declared performance : Dca-s2,d2,a3
Dealer locator
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania